PFM Crown Molar Case: Why the Old Crown Chipped, and What We Changed

This PFM crown molar case is a remake of a single crown on #30, the lower right first molar (FDI 46). Another lab made the first crown. About six years in, the porcelain broke off the mesial marginal ridge, and food started packing between #29 and #30 .

The Rx asked us to copy the old crown. We were happy to copy the outside. What we didn’t want to copy was the metal underneath it.

Final design · single crown · #30
#29
Adjacent
#30
PFM crown remake
#31
Adjacent
Nickel-free cobalt-chromium
Shade A3

Molar PFM Crown Case at a Glance

Restoration
PFM crown remake, #30, nickel-free Co-Cr
Shade
A3
Shape
Copied from the pre-op scan
Old crown
Chipped at the mesial marginal ridge
Opposing
Natural #3 and #4
Margins
Buccal shoulder, lingual chamfer

Patient Situation

Here’s what the dentist’s notes, scans and photos told us about this PFM crown molar remake :

Tooth: #30, vital, with a composite core under the old crown. No root canal.
Old crown: a PFM from another lab, about six years old, with porcelain covering the whole occlusal surface.
What broke: a piece of porcelain off the mesial marginal ridge and the mesial edge of the mesiobuccal cusp. Bare metal showed at the bottom of the chip.
The complaint: food packing between #29 and #30 since the chip. The contact itself was still there, but the ridge above it was gone.
Opposing teeth: natural #3 and #4, with no crowns. The palatal cusp of #4 lands right on the #29–#30 embrasure.
Wear: a few small facets on the opposing cusps, nothing the dentist called heavy. No night guard.
Gums: healthy. The buccal margin sits at the gum line, the lingual margin just above it.

The patient wanted a tooth-colored biting surface again and was fine with metal on the inside. They just didn’t want the new crown to break the same way.

What the Dentist Asked For

The Rx for this PFM crown molar, condensed :

Remake the PFM crown on #30 in nickel-free cobalt-chromium.
Same shape as the old crown, using the pre-op scan.
Porcelain on the occlusal surface, shade A3.
Normal contacts with #29 and #31.
Shoulder margin on the buccal, chamfer on the lingual, as prepped.

The dentist also put the old crown in the box, so we could look at it, and added one note: “Please tell me if anything looks wrong before you start.”

What the Old Crown Showed Us

The chip

The bare metal at the bottom of the chip is the old coping, so the chip tells you how much porcelain sat on top of it. Our technician measured 2.6 mm from the chip floor up to the edge of the porcelain still standing on the buccal side of the ridge .

That’s thick. We keep posterior porcelain at 1.5–2.0 mm and even. Porcelain is strong when metal backs it up and weak when it’s left hanging. Ceramic can fracture if it isn’t properly supported by the metal framework, and a marginal ridge is about as exposed as a spot gets.

The coping shape

Through the chip, the old coping looked like a thin, even cap that followed the prep . Nothing rose up under the ridge. So the porcelain ridge stood on its own, with the palatal cusp of #4 landing on it every time the patient bit down.

We can’t prove that’s the only reason it broke. Bite force and a hard bite on something can play a part too. But the coping shape is the part a lab controls.

Was there room?

Room for porcelain wasn’t the issue here. A posterior metal-ceramic prep calls for 2.0–2.5 mm of occlusal clearance under porcelain and 1.0–1.5 mm under metal. We measured the new prep against the opposing scan and the bite :

AreaReadingEnough for porcelain?
Mesiobuccal cusp2.2 mmYes
Distobuccal cusp2.1 mmYes
Mesiolingual cusp2.0 mmYes
Distolingual cusp2.0 mmYes
Mesial marginal ridge (prep to planned ridge top)3.1 mmYes, with room to spare
Distal marginal ridge (prep to planned ridge top)2.9 mmYes, with room to spare

That “room to spare” under the ridges is what matters most on a PFM crown on a molar. The prep drops off toward the proximal walls, so the marginal ridges have more height to fill than the cusps. If the coping stays flat, porcelain fills all of it.

PFM Crown Molar Options We Sent Before Making Anything

We sent the dentist a design screenshot, the chip measurement and three ways to build the new molar PFM crown :

OptionWhat it meansThe trade-off
A. Same outside shape, new copingThe coping rises under both marginal ridges so porcelain there stays 1.5–2.0 mm. Porcelain still covers the whole occlusal surfaceNo prep change and no visible metal. The ridges still carry porcelain, just backed by metal now
B. Option A, plus a metal mesial marginal ridgeThe ridge and the mesial contact are metal, so #4 bites on metal thereNothing left to chip at that spot, but a strip of metal shows when the patient opens wide
C. Metal occlusal surfaceAll the biting surface is metal, porcelain on the buccal onlyToughest of the three and needs the least room, but metal on the occlusal surface tends to show on lower teeth

We can build all three. The patient had asked for a tooth-colored biting surface, so the dentist picked A .

They also asked for a metal coping try-in. The old crown had let food pack in, and they wanted to check the seat, the margins and the space over the coping in the mouth before any porcelain went on. They approved the design in our WhatsApp group the same day .

How We Made This Molar PFM Crown

Coping design

Outside shape: copied from the pre-op scan, with the chipped ridge rebuilt to the height of #29's distal marginal ridge.
Cutback: the full-contour design was cut back evenly, so the coping keeps the shape of a smaller tooth instead of a flat cap.
Marginal ridges: the coping rises under both ridges, leaving 1.5–2.0 mm for porcelain on top .
Thickness: 0.3–0.5 mm on the axial walls and under the cusps, thicker under the marginal ridges.
Metal-porcelain junction: kept away from where #3 and #4 touch the crown.
Lingual: a thin metal collar on the chamfer, as the prep was cut for.

Metal coping

Our metal department cast the coping from the approved design . Before it left the lab, we checked its thickness with a caliper, looked at the margins under magnification for flash, and seated it on the printed model to make sure it didn’t press on the gums.

Coping try-in

The coping went to the clinic for the try-in. The dentist reported :

It seated fully, with closed margins on both sides.
No rocking.
With the patient biting on a VPS record over the coping, the thinnest spot over the mesial marginal ridge read 1.8 mm.

The dentist shipped the coping back with that bite record, and we kept going without changing the design.

Porcelain

The porcelain is matched to the alloy’s thermal expansion. The metal should expand slightly more than the ceramic, so the porcelain doesn’t end up in tension as it cools. Before the porcelain, the coping was blasted with aluminum oxide, cleaned ultrasonically and pre-oxidized so the porcelain bonds properly.

Then came opaque, then dentin and enamel porcelain in A3. The technician kept the layers even over the ridges and cusps, with no thick lumps over thin metal. We cap a PFM at three or four firings to keep the shape and color stable, and this crown took three . Each layer and firing went into the case record.

Final checks

Glazing and firing can move things a little, so we rechecked the contacts, bite and margins after the glaze. In a study of 3,750 single crowns, the remake rate was 3.8%, and proximal misfit, margin errors and esthetics were the most common reasons. So those get checked first.

Then we compared the crown with the approved design, and our QC technician signed it off against the Rx. It shipped in a foam-filled box.

Finished Result of the PFM Crown on a Molar

Here’s how this PFM crown molar case measured up at final inspection:

Design target
At final inspection
Outside shape copied from the pre-op scan, mesial ridge level with #29
Matched in a scan overlay; ridge level with #29
Coping 0.3–0.5 mm on the axial walls
0.4 mm
Porcelain over the mesial marginal ridge 1.5–2.0 mm
1.7 mm
Porcelain over the cusps 1.5–2.0 mm
1.6–1.8 mm
Contacts with #29 and #31, bite, margins to the Rx
All met
Shade A3
Matched under standardized light

Seating feedback

The dentist: the crown seated with no margin changes. The mesial contact held floss with a firm snap, and one light touch on the distobuccal cusp needed adjusting .

The patient: the biting surface matches the teeth next to it, and food stopped packing at the two-week check .

Sending a Similar PFM Crown Molar Case

Remaking a molar PFM crown that chipped, whoever made it first? This is how it works with us. For the full range, see our PFM crowns and our PFM crowns for molars and premolars. If the bite is short, we also make a PFM crown with metal occlusal.

Remakes: we take remakes of PFM crowns from other labs.
Coping try-in: ask for it on the Rx. It adds a trip to your clinic and back, so plan the appointments around it.
Records: scans from TRIOS, Medit, iTero, CEREC, Aoralscan or Planmeca. STL is fine for a back tooth. Physical impressions with a VPS bite are fine too, but please skip wax bites because they distort in transit.
Rx: use our Rx form, and see how to send a case.
Alloys: cobalt-chromium, semi-precious and high noble, and nickel-free on request. You can ask for composition and batch proof, and we never change a material without your OK.
Lead time: generally 5–7 working days at the lab. A design approval adds 1–2 days. You pay to ship impressions or models to us, and we pay to ship finished work back.
Warranty: 3 years on crowns. Open margins, open contacts, a high bite, a crown that won't seat or a wrong shade get remade free, and we cover the return shipping. Changing the shade or material later isn't free, and neither is a case we flagged for a poor impression and you asked us to try anyway.
Quotes: itemized to your Rx, not one bundled price. Ask for the price list.

Every step happens in our own labs: four of them in Shenzhen and Huizhou, China, with about 460 people. CAD design, metal and porcelain work and QC all run in-house, and metal and porcelain work are kept apart in production. Istar is an FDA-registered establishment, Registration Number 3039441248, which you can check in FDA’s establishment database. The lab runs under ISO 13485.

Got a molar PFM crown that keeps chipping in the same spot? Send us the scan, photos of the old crown and your Rx. We’ll measure the space and send you design options before we make anything. Send your first case or talk to us.

FAQ

Can I send just one test case?

Yes, single trial cases are welcome. Ongoing partnerships suit a regular case flow best, since international shipping is the big cost on one-off cases.

No. Photos and a scan taken before you remove it are usually enough to see where it broke. If you do have the crown, it’s worth putting in the box, because the chip lets us measure the porcelain over the old coping.

A slightly high bite is fine to adjust chairside. Polish the spot afterward so the surface stays smooth. If you see cracked porcelain, a crown that won’t seat or an open margin, stop and contact us.

Usually we do. Send photos and tell us what you adjusted, and we’ll work out the cause with you.

Yes, at no extra charge, for clients who send 10 or more cases a month. We guarantee the ship date. The arrival date depends on customs, so we can’t guarantee that.