FDA Reg. 3039441248 · EU MDR · UK MHRA · ISO 13485
9:30–18:00 China time (UTC+8)
Implant dental laboratory

Implant Dental Laboratory: Right System, Approved Design, Passive Fit

An implant restoration either seats, or it costs you chair time and another appointment. As an implant dental laboratory, Istar Digital builds every case to seat. Our implant department of about 80 people matches your scan body to the right library before design begins, works on original or compatible components as you choose, and sends custom abutments, bridges and full arches to you as a design to approve before anything is milled. Before a bridge or full arch ships, it has to drop onto the model under its own weight.

Custom abutment, Ti-base crown and full-arch implant bridge on models
About 80 people
In our implant department, with a dedicated full-arch team
Most implant systems
On original or compatible components, your choice
3–4 working days
Custom abutments; 5–7 for full-arch and All-on-X
3-year warranty
On implant restorations, with return shipping on us
01 · Products

What Our Implant Restorations Lab Makes

From a single abutment to a full arch on six implants, every product below is designed, milled, finished and inspected by our own technicians in our labs in Shenzhen and Huizhou. Nothing is sent out to another lab.

Custom Abutments

Milled for the individual patient, so the emergence profile, margin and angulation follow the tissue you’ve shaped instead of a catalog shape. You approve the emergence profile before the final abutment is milled, and it’s ready in 3–4 working days. Best for: the anterior esthetic zone, demanding soft tissue and implants placed off-axis.

Ti-Base Crowns

A zirconia or lithium disilicate crown bonded to a titanium base in our lab and delivered as one screw-retained piece. We blast and prime only the bonding surface and mask the implant interface, so no cement reaches it. Best for: retrievable single crowns where a prefabricated titanium connection suits the case. → Ti-Base Crowns

Screw- and Cement-Retained Implant Crowns

Screw-retained is our default: the crown comes off for maintenance and leaves no cement below the margin. When the axis puts the access hole on the facial surface, we solve it with an angled screw channel, a multi-unit abutment or a redesigned crown, and use cement retention only when none of those works. Best for: single implants anywhere in the arch, on stock or custom abutments.

Implant Bridges

Multi-unit bridges designed to one common path of insertion, with occlusion spread evenly and no lateral load on the implants. Every bridge has to seat on its analogs without rocking or spring-back. Screws never pull it into place. Best for: partially edentulous spans on two or more implants.

All-on-4 and All-on-X Bridges

Fixed full arches in monolithic zirconia or PFM, built by our dedicated full-arch team from your records. When you want a try-in, a PMMA prototype comes first. Full-arch cases take 5–7 working days in the lab. Best for: edentulous and failing dentitions restored on four or more implants. → All-on-X Full-Arch

Titanium Bar Restorations

Zirconia, resin or PMMA teeth on a titanium bar milled for passive fit, with room under the bar for cleaning and enough bonding area for the superstructure. We can supply the titanium bar and multi-unit abutments with the case, at extra cost. Best for: hybrid full arches where you want a metal framework under the teeth.

Immediate-Load and PMMA Provisionals

PMMA provisional bridges for immediate loading, and prototypes that test the occlusion, vertical dimension, midline and lip support before the final arch. A prototype stage usually takes 2–4 working days. Best for: loading on the day of surgery, and full arches you want to try in first. → Implant Provisionals

Implant Overdentures

Removable dentures on Locator, bar and other attachments, ordered to the attachment model you specify. Tell us the implant brand, connection, diameter, number and positions. Best for: patients who need a removable option on two or more implants. → Overdentures and Implant Overdentures

Surgical Guides

3D-printed guides to place the implants where the restoration needs them, so the screw channel and emergence are planned from the start. The guide stage usually takes 2–3 working days. Best for: guided placement on single, multiple and full-arch cases.

02 · Why Istar Digital

Why Dentists Choose Istar Digital as Their Implant Lab

Your System, Matched Before Design

Many implant misfits start before the milling machine: a wrong platform, or a scan body matched to the wrong library. A systematic review of scan-body accuracy ties scan precision to the scan body’s design, material and system. So our technicians check the scan body’s model, platform and connection against the manufacturer’s library before any design starts, keep each case on one library version, and verify library updates against physical components. If your lab works with its own libraries, we design on them.

Original or Compatible Parts: Your Call

We work with original manufacturer components and with compatible ones, and the treating clinician decides. We recommend original components for the most reliable fit and long-term stability. Compatible components cost less and fill the gap when a part is discontinued, though their tolerances and warranty terms differ. Nothing is ever substituted without your consent. Every component that passes through our implant restorations lab has its batch number and supplier on record, and we can return the original packaging with the case.

You Approve the Design, and Hear About Problems First

Custom abutments, implant bridges and full arches reach you as a design preview with screw-hole positions, connector sections and occlusal contacts marked, plus anything that concerns us, such as an unclear margin or a profile that will be hard to clean. Two revisions are included, and nothing is milled until you approve.

We don’t build around a problem and hope it seats. Your scan data is checked within one working day of arrival, so you hear about a gap, noise or a wrong bite right away. A damaged or mismatched component is never used; we tell you instead. If a production issue affects your date, you hear about it when it happens, not on the day the case was due.

Built and Checked to Seat

On the analog, every restoration has to seat without burrs, line up exactly, and stay put once the screw is tightened. Interfaces are inspected under magnification, and the screw has to turn in smoothly along the approved channel. Nothing leaves our implant restorations lab without final release by QC staff who don’t make restorations. Screws and small parts are counted, cushion-bagged, labeled with the case number, system and component specs, marked non-sterile, and checked by two people before they’re packed with the case.

03 · All-on-X

All-on-X, From Prototype to Final Arch

Full-arch work goes to a dedicated team inside our implant dental laboratory. A senior designer reviews every design, senior QC staff review every finished arch, and a technical lead adds a third review on complex cases.

1. Records. Send a full-arch scan with scan bodies, an accurate bite, a face-bow transfer or esthetic photos, CBCT data and the implant labels. With many implants, wide spacing or a long span, confirm their positions with a verification jig in the mouth first.

2. Prototype, when you want one. A PMMA prototype lets you check occlusion, vertical dimension, midline, lip support and seating in the mouth. Your feedback goes to a dedicated contact in your case chat.

3. Final arch. We carry the approved prototype’s occlusion, esthetics and screw channels into the definitive arch, but rebuild the fitting surface from the implant library instead of copying a surface that may have been adjusted chairside. The arch keeps the prototype’s form and still seats passively.

Every full arch is checked with the screws loose: it must seat under its own weight with no rocking. We check the midline, arch width and occlusal height on both sides, keep at least 2 mm of cleaning space to the mucosa, and have two people sign it off before it ships.

→ Records, structures and timing in full: All-on-X Full-Arch

04 · For dental labs

Implant Lab Capacity for Dental Labs

Short on implant capacity? Use Istar Digital as your implant lab and send us the whole case or just part of it: implant CAD design only, milling of your designs, or full production. We accept editable exocad and 3Shape files and work with your implant libraries and design parameters. Work goes out under your name, and we never contact your dentists.

05 · Working with us

Working With Our Implant Dental Laboratory

Start With One Implant Case

The fastest way to judge an implant dental laboratory is to seat its work. A single screw-retained crown on a Ti-base or custom abutment shows library matching, emergence profile and interface fit in one case. Single trial cases are welcome, and an ongoing partnership works best with a regular flow of cases.

Turnaround and Free Rush

Lab time counts in working days from the day a complete case arrives; staged cases add the time your clinic needs for each try-in. If you send 10 or more cases a month, rush service is free for every case type. We guarantee a rush case’s ship date; arrival depends on transit and customs.

Itemized Quotes

The number of units sets the base, the material sets the unit price, and implant components and design complexity are added on top. Quotes are itemized to your requirements, never bundled into one figure. Your sales manager sends the current price list on request.

Warranty and Credentials

Implant restorations carry a 3-year warranty, and we pay to ship finished work and remakes back to you; implant components aren’t covered by a free remake (Remake and Warranty Policy). Istar Digital is an FDA-registered establishment, Registration Number 3039441248, listed in the FDA establishment registration database for custom implant abutments and implant superstructures, not implant bodies. Our labs run an ISO 13485 quality management system, and restorations for the EU follow the MDR custom-made device procedure.

06 · FAQ

Frequently Asked Questions

What should we send for a single implant crown?

An intraoral scan with the scan body seated, the opposing arch and an accurate bite, plus photos of the implant and scan-body labels showing brand, platform, connection, diameter and the scan-body model. Add a full-face smile photo, an intraoral photo in occlusion and a shade photo, and a scan of the healing abutment or provisional so we can follow the tissue. → File formats and scanners: Send a Case guide

Neither is free of complications. The ITI consensus on screw- and cement-retained reconstructions found more technical complications, fistulas and suppuration with cemented work and more ceramic chipping with screw-retained work, and makes no universal recommendation. We default to screw retention for retrievability, and recommend cement when the access hole would open facially or very high esthetic demands leave room for an abutment and crown.

Yes. We accept VPS (our first choice), condensation silicone and polyether impressions, as well as stone or 3D-printed implant models with analogs. For the bite, use a PVS or polyether registration rather than wax, which softens in transit and leaves the bite low.

We can give a reference value, but the torque that counts is the one in the implant system’s instructions for use. Always follow the manufacturer.

For a loose screw or interface, check whether the torque was reached, whether original and compatible parts were mixed, and whether the interface shows wear or a micro-gap. Send us photos, and we’ll investigate with you and, where needed, the component manufacturer. For a full arch that won’t seat, start with the scan data and implant positions, then the model or verification jig, and only then the framework.

Send Us Your Next Implant Case

Tell us the implant systems you restore, the cases you send most (single crowns, bridges or full arches), whether you prefer original or compatible components, and your approximate monthly volume. Your sales manager will reply with the price list and confirm we have the right libraries for your systems, so your first case can go straight into design when it reaches our implant lab.