FDA Reg. 3039441248 · EU MDR · UK MHRA · ISO 13485
9:30–18:00 China time (UTC+8)
Implant crowns

Zirconia Implant Crowns

A zirconia implant crown from Istar Digital Dental Lab is made to the dentist’s Rx for titanium implants, from your scan-body file or implant-level impression. We make them for dental clinics, DSOs and dental labs in the US and Europe.

The crown is the easy part. Whether it seats on the first try depends on the components around it, and on catching a mismatch before anything is milled.

Zirconia implant crown bonded to a Ti-base
5–7 working days
Lab time, from complete records
3-year warranty
On zirconia implant crowns
Screw-retained first
Our default recommendation
OEM or compatible
Your choice, never swapped without approval
01 · Builds

Three ways to order a zirconia implant crown

Most quote confusion starts here. “Implant crown” can mean the crown alone or the full assembly that screws into the implant, and the two are priced and built differently.

Build
What you receive
Where it fits
Crown bonded to a Ti-base
A zirconia crown bonded to a titanium base in our lab, with the prosthetic screw. It screws directly into the implant.
Most posterior and many anterior single units
Crown on a custom abutment
A custom abutment shaped to the site, plus a zirconia crown that is screwed or cemented to it
Esthetic zones, deep or uneven soft tissue, or implants placed off-axis
Crown only
The zirconia crown alone, designed to a stock or custom abutment that is already in place or that you supply
Clinics re-crowning an existing abutment; labs that handle their own components

Not every case needs a custom abutment: a stock abutment works well where the implant position is ideal and function comes first.

OEM or compatible components

We work with both original-manufacturer (OEM) components and compatible components. OEM parts give the most predictable fit and long-term stability, and they’re our first recommendation. A well-validated compatible part is a reasonable alternative, for example when an OEM part is discontinued, but its machining tolerances, material and warranty usually differ from the original.

The choice is yours as the treating clinician, not ours. We never swap a component, or a material, without asking first, and nothing changes without your written or verbal approval. Every component we use is recorded by lot number and supplier, so it can be traced back to its packaging. If you want the original component packaging returned with the case, ask and we’ll ship it back with the restoration.

02 · Retention

Screw-retained or cement-retained

Our default recommendation is screw-retained: the crown can be removed for service without being cut off.

That preference has clinical support. In a five-year randomized trial of cemented versus screw-retained zirconia-based implant crowns, survival didn’t differ between the groups, but the cemented restorations had more biological and overall complications. The trial used one-piece zirconia abutments, so it isn’t a forecast for every Ti-base crown, but the underlying problem is general: residual cement at a submucosal margin is hard to find and harder to remove.

Cement retention still has its place: when there is enough restorative space and the esthetic demand is high enough that any access opening is unacceptable, or as the fallback when a facial channel can’t be redirected.

When the screw channel lands in the wrong place

An implant angled so far buccally or lingually that the channel would open on the facial surface doesn’t automatically mean a cemented crown. In order of preference, we look at:

  1. An angled screw channel (ASC) with a matching angled abutment, using a library that supports it and never beyond the maximum angle the component manufacturer allows.
  2. A multi-unit abutment (MUA) to correct the angle.
  3. Redesigning the crown contour to move the access opening to the lingual or a non-esthetic surface.
  4. Cement retention, when none of the above works.

In CAD we plan the channel along the implant’s long axis and place the opening in the occlusal fossa where we can, away from occlusal and proximal contacts.

03 · Zirconia

Choosing the zirconia

Zirconia for implant crowns comes in three practical forms. The trade-off is the same one you know from tooth-borne crowns: strength and translucency pull against each other, and thickness is the factor that buys you both.

Type
What it is
Typical use on implants
Monolithic (single-layer)
One homogeneous block of zirconia, stained and glazed or polished
Posterior crowns, heavy occlusion
Multilayer monolithic
Still one piece, but the blank grades from a denser cervical area to a more translucent incisal edge
First choice for full-contour anterior crowns
Layered (veneered)
A zirconia substructure with feldspathic porcelain built up on the facial, or a micro-layer for characterization
Highest-esthetic anterior cases with a stable occlusion

The main mechanical difference between them is chipping. A systematic review of implant-supported ceramic single crowns found annual ceramic chipping of 1.65% for veneered crowns versus 0.39% for monolithic crowns, and crown location, anterior or posterior, didn’t change survival or chipping rates. The same review notes that the monolithic zirconia data still have shorter follow-up than the veneered data. So where esthetics allow, a monolithic or multilayer crown takes the most common failure off the table.

Our zirconia materials include Aidite, Wieland, Zirkonzahn and 3M Lava, and we’ll produce with a specific brand or batch if you need one. On request, a case can ship with proof of the material used: brand, origin and batch number.

Bruxism and heavy occlusion

For patients who grind, monolithic zirconia with a polished occlusal surface is our usual recommendation. That doesn’t make bruxism a non-issue. A 2024 meta-analysis found bruxism to be a probable risk factor for mechanical complications in implant-supported crowns, with a pooled odds ratio of 4.68. Note the bruxism on the Rx, so we can keep the crown as thick as space allows and the contacts even. Night-time protection is the treating team’s call, and we make custom dental guards too.

04 · Restorative space

Restorative space, wall thickness and the screw channel

There is no single minimum thickness for a zirconia implant crown. Each zirconia blank has its own minimum in the manufacturer’s instructions, and the Ti-base or abutment adds limits of its own. The preparation guidelines you use for a crown on a natural tooth don’t transfer either: there’s no stump, and the screw channel takes ceramic out of the middle of the crown.

That channel is where the crown is weakest, and the axial wall around it matters more than many expect. In a laboratory study of monolithic zirconia implant crowns with screw holes, increasing axial thickness from 0.8 to 1.2 mm raised fracture load more than doubling occlusal thickness from 0.5 to 1.0 mm. The authors recommend at least 1.2 mm of axial wall when occlusal thickness is limited. It’s a single in-vitro study, but it matches what we see in design: a tall Ti-base in a short space leaves very little ceramic around the channel.

What we do about it:

  • We measure the restorative space and tell you before production if it’s short, so the crown isn’t simply milled thinner than its material allows.
  • We lay out the options when space is short: a high-strength material that tolerates a thinner section, a space-saving design, or adjusting the opposing tooth, with the amount of reduction needed.
  • Your call, on the record. If you still want a crown made below the material’s minimum after we’ve flagged it, we make it, but a remake caused by that decision isn’t covered.
05 · Records

What to send for a dental implant zirconia crown

Most implant remakes trace back to one missing detail at intake: the wrong platform, a scan body matched to the wrong library, or no record of the soft tissue.

Implant identification

  • Implant brand and system, for example Straumann, Nobel Biocare or MIS
  • Platform diameter (NP/RP/WP or the size in mm) and connection type (internal conical, internal hex, external hex, tri-channel and so on)
  • Implant diameter and length
  • A photo of the implant packaging label, or the product code
  • For digital cases, the scan body brand, model and the CAD library name

We check every case against this list before design starts. In CAD we then overlay the virtual scan body on your scan and confirm the interface lines up before anything is designed on top of it.

Scans and impressions

  • Digital: an intraoral scan with the scan body fully seated, the opposing arch and a bite scan. We accept 3Shape TRIOS, iTero, Medit, Primescan, Shining 3D, DEXIS and other scanners, as STL, PLY, OBJ or 3Shape files, sent directly or by WeTransfer. For anterior cases, send a PLY with color, so we can see the gingiva. More on file handling is on our digital dental laboratory page.
  • Conventional: an implant-level impression in VPS (preferred) or polyether, with the impression coping and analog, or a poured model with the analog in place. Don’t send alginate internationally; it shrinks and distorts in transit. Use a VPS bite registration, not wax, which softens and deforms in shipping.
  • Photos: a full smile, an intraoral view in occlusion, and a shade photo.
  • Soft tissue: a scan of the healing abutment or provisional crown, or of the tissue cuff, so we can design the emergence profile to the site.

CAD libraries

We use original-manufacturer libraries first. Third-party libraries are checked for dimensional accuracy before use, every library version is logged, and a case is never designed across two versions. If your scan body needs your own library, send it with the case and we’ll design with it.

The Rx

A complete implant crown Rx states the tooth number, the build (Ti-base, custom abutment or crown only), OEM or compatible components, the retention method, and the zirconia type, brand if required, and shade. Download the Istar Digital Rx form and follow How to Send for packaging and courier details.

06 · Make & check

How we make and check each crown

Every zirconia implant crown is made in our own labs, from file intake and CAD design through milling, sintering, staining, glazing, bonding and inspection. Nothing is outsourced.

Design approval. The emergence profile is designed from your soft-tissue record, narrow at the platform and widening smoothly to the crown. That design, the screw channel angle and any custom abutment go to you for approval before milling. We send screenshots or the STL by email or your case chat, with one design and two free revisions.

Milling and sintering. Shrinkage compensation is set from the zirconia manufacturer’s data and checked against a standard test block for each material batch. Sintering programs are fixed, with locked temperature, heating rate and hold time; furnace temperatures are verified with test pieces, and the curve of every firing is logged. A new material or batch is test-fired before it goes into production.

Ti-base bonding. Bonding steps differ between Ti-base designs, so we follow the Ti-base manufacturer’s instructions for the exact part. The implant interface is masked before surface treatment, only the bonding surfaces are conditioned, and a metal primer and resin cement are used with a controlled cement space. Excess cement is removed while it’s still soft, especially around the interface, and the assembly is checked under magnification after curing.

Inspection. Every case passes three quality checks: at intake, during production and a final release by an independent inspector. Implant crowns get additional checks: the interface on the analog for seating and burrs, the screw channel angle and diameter, a screw that threads in smoothly, passive seating without force, and a match between every component and the Rx. QC photos are available before shipping on request.

Packaging. Prosthetic screws and small parts go in their own sealed bag, labeled with the case number, and are double-checked against the work order before the box is closed.

07 · Warranty

Lead time, warranty and remakes

  • Lab time: 5–7 working days from the day we have complete records. Time spent waiting for missing information or your design approval isn’t counted.
  • Rush cases: free for clients who send 10 or more cases a month. We guarantee the ship date. We can’t guarantee the arrival date, because customs clearance is outside our control.
  • Shipping: you pay to send impressions or models to us. We pay to ship finished work back, remakes included.
  • Warranty: 3 years on zirconia implant crowns.
  • Free remakes: for lab-side problems, such as a crown that won’t seat, an open margin or contact, a high occlusion, an inaccurate shade or a visible defect.
  • Not covered: shade or material changes you request after production, and cases we made at your request from records we had already flagged as unclear.
  • Implant components: a free remake covers our work, not implant parts. Ti-bases, abutments and screws used in a remake are charged.

If a crown chips but seats well, we can usually remake it from the original data. If the problem is seating, margins or occlusion, we need a new scan or impression, because the old record can’t show what went wrong.

08 · About Istar Digital

Why clinics and labs send implant work to Istar Digital

Istar Digital was founded in 2012 and runs four dental labs in Shenzhen and Huizhou, China, with about 460 employees. About 80 of them work in our dedicated implant department.

Measured quality

95% of cases pass final inspection at Istar Digital. That’s a separate number from our overall remake rate of 2–3%, which counts cases clients send back.

Regulatory

Istar Digital is an FDA-registered establishment, Registration Number 3039441248, which you can verify in the FDA establishment registration database. Our labs work under an ISO 13485 quality management system.

The rest of your implant work

the same team makes implant-supported bridges, PFM implant crowns and full-arch cases. See our implant dental laboratory for the full range.

See it first

book a visit to our labs in Shenzhen or Huizhou, or a live video tour.

09 · FAQ

FAQ

How is a zirconia implant crown priced?

Quotes are itemized to your requirements, not one bundled price. Pricing starts from the number of units at a base price set by the material; implant components and design complexity are added on top. OEM components are charged at the manufacturer’s price plus our work, so they cost more than compatible parts. We confirm the full cost before production starts.

Yes. We accept editable exocad and 3Shape designs and produce them as designed. When you supply the design, remakes for seating or occlusion are on the design side; chipped or fractured ceramic is on ours.

Torque always follows the implant manufacturer’s instructions for that system; we can give a reference value, but the manufacturer’s figure is the one that counts. When a screw loosens or breaks, check that torque first, then whether OEM and compatible parts were mixed, then the interface for wear or a gap. Send us photos and the parts, and we’ll analyze the failure with you, or with the component manufacturer.

Yes. Packaging, labels and paperwork can go out without the Istar Digital name, and we can ship to any address you give us. The sender address on the courier waybill can’t be changed.

Send your first zirconia implant crown

Single trial cases are welcome, and that’s how many clients start. Pick a single posterior implant with a scan body file, fill in the Rx and send it to us. You’ll see how the crown and its components seat on your own case before you commit to more. Ongoing partnerships work best with a regular case flow, which keeps international shipping cost-effective.