FDA Reg. 3039441248 · EU MDR · UK MHRA · ISO 13485
9:30–18:00 China time (UTC+8)
Case study
Crowns & Bridges
Inlays & Onlays

Ceramic Inlays and Onlays Case: #29 Inlay and #30 Onlay

This ceramic inlays and onlays case came in as two teeth side by side on one Rx: a DO inlay on #29 and an MOD onlay on #30, covering the buccal cusps .

Either one alone is routine. The real job was getting two restorations to work like one row of teeth.

Final design · inlay and onlay · #29–#30
#28
Natural
#29
e.max Press inlay
#30
e.max Press onlay
#31
Natural
At least 2 mm of ceramic over covered cusps
Shade A3 on both

Ceramic Inlay and Onlay Case at a Glance

Restorations
#29 inlay and #30 onlay, IPS e.max Press
Old work
#29 DO amalgam, #30 MOD amalgam
Pulp
Vital on both
Cusp coverage
At least 2 mm of ceramic
Contacts
Normal; floss passes between #29 and #30
Shade
A3 on both

Patient Situation

The patient is an adult in their mid-40s, with no grinding or clenching reported . Both teeth had old amalgams. At a recall visit, the dentist found margin breakdown and decay where the two restorations met .

With the amalgam and decay out, the dentist’s notes and the first scan recorded :

#29 (lower right second premolar)#30 (lower right first molar)
Old restorationDO amalgamMOD amalgam
PulpVitalVital
Buccal sideWall about 2.6 mm thickWalls about 1.4 mm thick, undermining the mesiobuccal, distobuccal and distal cusps
Lingual sideWall about 2.4 mm thickWalls about 2.7 mm thick, cusps sound
Cavity colorClean, light dentinGray staining on the pulpal floor from the old amalgam
MarginsOn enamel, box floor 1 mm above the gumOn enamel, mesial box floor right at the gumline
Other neighbor#28, natural and untouched#31, natural, needs a rebuilt contact
Shows in a smile?Yes, in a normal smileBuccal margin only, in a wide smile

Why This Case Needed a Dental Ceramic Inlay and an Onlay

The dentist made each of these calls .

#29 got an inlay

The cavity was wide, but nothing needed covering. A review of ceramic inlays in posterior teeth names excessive isthmus width as a spot where a dental ceramic inlay is a real option over direct composite.

#30 got an onlay

The buccal cusps take load on a lower molar, and their walls were too thin to leave alone. One restorative dentist’s published onlay protocol reduces and covers any cusp under 2 mm thick.

#30 didn't get a crown

The dentist wanted to keep the lingual cusps. That same article cites a preparation study that put tooth removal at 39% for an MOD onlay and 72.3% for a full crown. It’s one study on one prep design, not a general rule, but it shows the kind of difference the dentist was weighing.

Nothing went to metal

The patient asked for tooth-colored work.

What the Dentist Asked For

The Rx and notes on this ceramic inlays and onlays case asked for :

IPS e.max Press for both restorations.
At least 2 mm of ceramic over the covered cusps.
Normal contact between #29 and #30, with floss able to pass.
Normal contact between #30 and #31.
Either piece can go in first. The dentist wanted that freedom at bonding.
Shade A3 on both, reading as one family with #28 and #31.
No gray showing through #30.
See the design before pressing.

The Technical Problems in This Ceramic Inlays and Onlays Case

One contact, no natural wall to copy

Normally a proximal contact is built against a neighbor that’s already there. Here, the #29 distal box faced the #30 mesial box. Both surfaces would be new. So the contact had no fixed reference, and its height, position and tightness all had to come from the design.

Two pieces that get in each other's way

Each restoration has its own path of insertion, set by its own boxes. If the contact bulges too much, the first piece in blocks the second. A contact that seems fine on a single die can bind once both pieces are on the model, and here it had to clear in both orders.

Same A3, different result

A small dental ceramic inlay has tooth all around it, so it borrows color from the enamel. The onlay on #30 is bigger, with more ceramic, less tooth behind it and a darker background. The same review ties a good dental ceramic inlay match to both the right shade and the right translucency. So one ingot for both teeth wasn’t a safe bet.

Getting enough ceramic over the cusps

A systematic review of ceramic onlays says longevity can improve when the prep allows at least 2 mm of occlusal ceramic, which is where the Rx figure came from. Whether the space was really there was up to the scan.

What We Found on the First Scan

Our team checked the intraoral scans, shade photos and Rx for this porcelain inlay onlay case before any design work. Three things came up :

What we sawWhy it matteredWhat happened
The #30 mesial box margin was blurred at the gumline, with tissue covering part of itWe’d be guessing at a margin right at the shared contactWe asked for a new scan after retraction
1.5 mm of clearance over the distobuccal cusp of #30The Rx figure couldn’t be met thereWe sent the dentist three options
A 0.2 mm undercut on the lingual wall of the #30 mesial boxIt could stop the onlay from seatingSmall enough to block out in the design, so we did and told the dentist

We posted marked-up screenshots in the case’s WhatsApp group the same day .

The clearance options :

Reduce the cusp another 0.5 mm. Takes one more short visit and a new scan, and reaches 2 mm.
Adjust the opposing #3. Saves the cusp on #30, but cuts a tooth that had nothing wrong with it.
Keep 1.5 mm. No extra work, but thinner ceramic right where the tooth takes load.

The dentist picked the first one, since the patient had to come back for the retraction and rescan anyway .

The Porcelain Inlay Onlay Material: Pressed Lithium Disilicate

Plenty of dentists still write “porcelain inlay onlay” on the Rx. Ivoclar lists IPS e.max Press for both inlays and onlays. We press our e.max inlays and onlays. We don’t mill them. The review notes that inlays made from heat-pressed ceramics tend to show excellent marginal adaptation and good fracture resistance.

Lithium disilicate runs 250–400 MPa in flexural strength, according to the ADA. Those numbers depend on the test method, so don’t read too much into them.

We never swap a material without the client’s OK, written or verbal. If your Rx names a specific brand or batch, we can work to that, and we can provide the brand, origin, batch number and certificates for the material on a case when you ask.

How We Met Each Requirement

RequirementWhat we didHow we checked it
MaterialDesigned both restorations together, in one file on the same scanMaterial checked against the Rx before pressing
Cusp thicknessBuilt the onlay on the new scan, with 2.0 mm at the distobuccal cusp, the tightest spotThickness measured in the design software
#29–#30 contactSet it at the junction of the occlusal and middle thirds, about 2.5 mm wide, and kept the gingival embrasure openChecked with both pieces on the model
#30–#31 contactMatched the contact height on #31’s mesial surfaceChecked on the model
Seating orderRounded the contact surfaces so neither piece has to pass a bulge on the otherRan it in the software, then seated them both ways on the model
ShadePressed #29 in a higher-translucency ingot and #30 in a lower oneCompared with the shade photos under standard light
Stain maskingPicked the #30 ingot from the photo of the prepared toothChecked over a gray-tinted die
Design approvalSent the design for review with nothing pressed yetPressing started only after the dentist’s approval

Making This Ceramic Inlays and Onlays Case, Step by Step

Day 1 : first scan and Rx in.
Day 2 : new scan in, with the margin clear and the cusp reduced. CAD design starts.
Days 3–4 : the design went out on day 3. The dentist asked us to open the buccal embrasure between #29 and #30 a little, so it would look more like the natural space between #28 and #29, and approved the revision on day 4.
Day 5 : pressing, then a first fit on the printed model, before any color work.
Day 6 : stain and glaze. After the first stain, #30 read a bit brighter than #29, so the technician added warmer stain at the cervical third of its buccal surface. Then a light fissure stain on both, matched to #31. Glazing can shift a contact a little, so the contacts got a second check.
Day 7 : final inspection, then shipping in a foam-filled box. Our QC team checked margin fit, inner surfaces and the bite in centric and excursions. They also looked for cracks, pores and chips under inspection lighting, and compared the shape and color against the approved design.

Bonding Notes Sent With the Case

A pressed dental ceramic inlay or onlay gets bonded with resin cement, like Variolink or RelyX Ultimate. We shipped both inner surfaces clean, ready for the dentist’s own etch and silane .

The dentist’s plan was to try both pieces in together, then bond #30 first and #29 second, rechecking the contact in between . That order was their choice. Isolation matters here, too. The review calls proper isolation imperative and highly recommends a rubber dam, and on two adjacent teeth, excess cement has one more place to hide.

The Finished Ceramic Inlays and Onlays

Design goal
At try-in and bonding
Both seat without force
Both seated fully on the first try, each alone and together
#29–#30 contact
Floss passed with a firm snap, no adjustment
#30–#31 contact
A little tight, one polish pass by the dentist, then fine
Margins
No gap seen, no margin adjustment
Bite
One light high spot on #30 after bonding, adjusted and polished by the dentist
Color
With try-in paste, #29 and #30 read as one family with #28 and #31
Gray dentin on #30
Not visible through the ceramic

Checking the bite after bonding is normal on this kind of work. The review says it’s often the most practical way to do it, and that chairside finishing can leave a rougher surface. That’s why we try to send porcelain inlay onlay work that needs very little grinding.

Dentist and patient feedback

From the dentist’s message after the bonding visit :

The dentist

said the extra visit was a fair price for the clearance.

The patient

said the bite felt normal by the end of the appointment.

Sending Your Own Ceramic Inlays and Onlays Case

For adjacent preps like these, a few extra things help:

Scan the shared area carefully. Retract before you scan, then take it slowly around both boxes. Trace each margin by hand instead of leaving it to auto-detect. Then send the case to us.
Send two photos. The natural tooth next to a shade tab, and each prepared tooth next to a shade tab, in the same frame. Keep the camera settings simple, since flash, polarizers and white balance all change how color reads.
Say what you want on the Rx. Tooth numbers, surfaces, cusps to cover, shade, contact tightness, and whether you need a set seating order. Use our Rx form.
Ask for design approval up front. It adds 1–2 days.

Our lead time for ceramic inlays and onlays is generally 5–7 working days. Simple cases can take 2–3. For the full product range, see our ceramic inlays and onlays, inlays and onlays and e.max dental lab pages.

Who Made It

This ceramic inlays and onlays case went through our CAD design department (about 100 people), our ceramic and metal department (about 70) and a separate quality control team (about 25). They all work inside Istar Digital Dental Lab’s four labs in Shenzhen and Huizhou, China. We’ve been running since 2012, have about 460 employees and don’t outsource any step.

Istar Digital Dental Lab is an FDA-registered establishment (Registration Number 3039441248), and you can look that up in the FDA establishment registration database. Our labs run an ISO 13485 quality management system. For the EU, custom-made devices follow the MDR custom-made device procedure. You’re welcome to visit the factory or book a video tour.

Porcelain Inlay Onlay FAQ

What if my patient grinds or clenches?

Put it on the Rx. We’d increase the occlusal thickness and keep contacts flat and evenly spread. The evidence is mixed: the onlay review linked parafunction with more failure, while a study of 547 glass-ceramic restorations found no greater risk with bruxism.

We’ll tell you what we see and what you could change. If you still want it, we’ll make it to your Rx. You don’t need to sign anything, but problems that come from that design, remakes included, aren’t on our side.

3Shape TRIOS, Medit, iTero, CEREC, Shining3D and Planmeca, plus any scanner that exports open files. iTero and CEREC need to export STL or PLY, since we can’t open their proprietary files.

Yes. Send VPS impressions of the prep and opposing arch with a VPS bite registration. Skip wax bites, because they soften and distort in transit.

Yes, in composite or PMMA, including 3D-printed ones. Ask when you send the case.

Three years. We remake free of charge for problems on our side, like an open margin, an open contact, a high bite, a restoration that won’t seat or an inaccurate shade. Changing the shade or material afterward isn’t free, and neither is a poor impression we flagged and you asked us to run anyway. You pay to send a case in, and we pay to ship finished work back, remakes included.

Rush service is free for clients who send us 10 or more cases a month, for any material or case type. We guarantee the ship date. We can’t guarantee the arrival date, because customs times vary.

We don’t publish prices on the website. Ask for our price list, and we’ll quote each case item by item. Single trial cases are welcome, and ongoing partnerships suit clinics with a regular case flow.

Got Two Adjacent Preps Coming Up?

Send us the scan of your next ceramic inlays and onlays case and ask for a prep check. We’ll look at the margins, the clearance and the shared contact, and tell you what we see before anything gets made.