FDA Reg. 3039441248 · EU MDR · UK MHRA · ISO 13485
9:30–18:00 China time (UTC+8)
Case study
Crowns & Bridges
E.max

Emax Crowns Front Teeth Case: Same Shape, Enough Ceramic

This emax crowns front teeth case is four pressed crowns on #7–#10 . The Rx had one firm rule: copy the shape the patient already had. Then the prep scan showed two teeth without enough room for the ceramic on the facial . So we had a choice to make before anything got pressed: bulky necks, thin ceramic, or a little more prep.

Final design · four single crowns · #7–#10
#6
Natural canine
#7
e.max Press
#8
e.max Press
#9
e.max Press
#10
e.max Press
#11
Natural canine
Not splinted
Target shade A2

Anterior E.max Crowns Case at a Glance

Restorations
4 single anterior emax crowns, not splinted
Teeth
Universal #7–#10 (FDI 12–22)
Material
IPS e.max Press lithium disilicate, pressed, stained and glazed
Target shade
A2
Stump shade
A3 on all four, including the composite build-ups
The catch
Facial room on #8 and #9 at 0.7–0.8 mm
Extras
Printed reduction guide, printed provisionals
Lab time
6 working days, design approval included. Days spent waiting on the extra visit and rescan not counted

Patient Situation

Before we planned the emax crowns front teeth, here’s what the dentist’s scans, photos and notes showed :

Teeth: #7–#10 all had large old composites. Edges were chipped and the margins had picked up stain. #8 and #9 had both incisal corners built up in composite.
Pulp: all four vital. No root canals, no posts.
Stumps: A3, and the composite build-ups were close to A3 too. So dark stumps weren't the problem on this one.
Bite: about 2.5 mm overbite. The lower incisors touch the palatal of #8 and #9 in the middle third. The natural canines, #6 and #11, guide the side movements.
Gums: healthy, even margins, a medium smile line.
Patient's ask: "brighter, but don't change my teeth." They liked their size, length and outline, and didn't want a new smile.

That last point shaped the whole case. Instead of a wax-up of something new, it started with a scan of something old.

Why anterior emax crowns and not veneers here

With that much old composite, there wasn’t much sound enamel left on the facial and proximal surfaces . Crowns made sense on these four teeth. That isn’t a general rule. A narrative review on lithium disilicate and zirconia sits behind the usual advice: crown a tooth when it’s structurally compromised, not just to change how it looks. The choice was the dentist’s.

What the Dentist Asked For

The Rx, condensed :

Four single anterior emax crowns, #7–#10, in IPS e.max Press. No splinting.
Copy the pre-op shape: length, facial outline, incisal edges and embrasures.
Shade A2. Stump A3.
Rounded shoulder. Adhesive bonding.
Show the design before pressing.
Printed provisionals from the approved design, as single units.
Ship all four crowns together.

Item 6 was there for a reason. A splinted provisional hides how each tooth reads on its own. Single units let the dentist and patient judge every outline before the ceramic is made.

What Came In

The records the dentist sent for the emax crowns front teeth :

RecordWhat we used it for
Pre-op PLY scan of #7–#10, taken before any prepThe shape to copy
Prep PLY scan, upper archMargins, inner surfaces, available room
Opposing arch and bite scanOverbite, palatal contacts, guidance
Smile and retracted photos, 5500K ring flashValue, edge effects, surface texture
Tab photos next to the natural canine and next to each stumpTarget shade and stump shade

The pre-op scan was the most important file in this anterior emax crowns case. Without it, “copy the shape” is just a wish. PLY matters on front teeth too, because it carries color, gum margins and surface detail. STL doesn’t. All of it went through our digital workflow.

We ask for flash photos, not phone shots or room light. Phone filters and mixed light shift the color, and then the technician is guessing. Having the tab next to the stump matters for pressed emax crowns in particular. Ivoclar’s shade selection guidance uses the prep shade and layer thickness, not just the target shade.

The Technical Problem: Not Enough Room on #8 and #9

How we measured it

We lined up the pre-op scan and the prep scan on the untouched teeth and the palate . The gap between the old outer surface and the new prep surface is the room the crown gets, if the crown is going to copy the old shape. We mapped it in thirds for all four anterior emax crowns .

ToothIncisalFacial, middle thirdFacial, cervical thirdPalatal
#71.6 mm1.3 mm1.2 mm1.3 mm
#81.8 mm0.8 mm0.7 mm1.4 mm
#91.7 mm0.8 mm0.7 mm1.4 mm
#101.6 mm1.3 mm1.2 mm1.3 mm

All values .

What the numbers meant

For these emax crowns front teeth, we used Ivoclar’s figures for a conventional pressed anterior crown: about 1.5 mm incisal and 1.2 mm facial and palatal, with a rounded shoulder or deep chamfer at least 1 mm wide. A prospective study of pressed lithium disilicate crowns, mostly on front teeth, used a similar prep. #7 and #10 cleared it. #8 and #9 came up 0.4–0.5 mm short on the facial, right where the patient would notice.

Ivoclar does describe a thinner, 1 mm crown design. It only works with adhesive cementation, and it rules out bruxism and missing canine guidance. This patient had neither problem, and the Rx already said adhesive. But at 0.7–0.8 mm, #8 and #9 were still under that 1 mm floor.

Why we didn't just press it

This is how front crowns end up looking too big. If the prep under pressed emax crowns is short, the lab has two ways to get the ceramic thick enough, and both are bad:

Build outward. The crown gets thick enough, but the facial sits proud of the old tooth. That's the "too big, too round" look.
Copy the shape anyway. The outline matches, but the ceramic is thinner than the material is meant to be.

Neither one is what the Rx asked for. So we paused the case before design approval and contacted the dentist .

The Options We Sent

We sent the thickness map, a side view of #8 and #9 with both outlines laid over each other, and four options :

OptionWhat happensThe catchDentist’s call
1. Press on the current prep, full thicknessNo new prepNecks of #8 and #9 sit 0.4–0.5 mm proud of the old outline. Not a copy anymoreNo
2. Copy the outline, press thinShape matches exactly0.7–0.8 mm of ceramic, under the 1 mm floor for an adhesive crownNo
3. Take 0.4–0.5 mm more off the facial of #8 and #9, with a printed guideShape and thickness both holdOne more short visit, a rescan, and a bit more tooth structure on two teethYes
4. Switch #8 and #9 to full-contour zirconiaDifferent material, different thickness rulesTwo materials side by side in the middle of the smileNo

The dentist picked option 3 the same day . Their reasoning: the patient came in for “don’t change my teeth,” and options 1 and 4 would have changed them. Option 2 would have looked right on delivery day and put the risk on later.

If the dentist had picked option 1 or 2, we’d have made it to the Rx, with no form to sign. Problems coming from that choice, remakes included, wouldn’t be ours to cover. Our job was to show the trade-off clearly, not to make the call.

How We Copied the Shape Into Four Anterior Emax Crowns

Step 1: The copy design

We copied the pre-op outer surface onto all four pressed emax crowns . The inner surfaces of #8 and #9 were set to the planned prep, 0.4–0.5 mm deeper on the facial, so the outer shape didn’t move at all .

During design approval, the dentist asked for one change from the copy. The old composites had closed the incisal embrasure between #8 and #9, and the dentist wanted it opened by 0.2 mm . Everything else stayed as copied. The dentist approved the design in writing .

Every front multi-unit all-ceramic case gets design approval before production here.

Step 2: The reduction guide and provisionals

From the approved design, we printed two things and sent them together :

A reduction guide for #8 and #9. It sits on the teeth and shows how much facial needs to come off, zone by zone. It only covers the two short teeth, so #7 and #10 weren't touched again.
Four single printed provisionals in the approved shape, embrasure change included.

The dentist used the guide, rescanned #8 and #9, and relined the provisionals chairside . On the rescan, the facial room on both teeth read 1.2–1.3 mm . We sent back a short thickness screenshot to confirm, then moved on to the final crowns.

A quick note on provisionals. On emax crowns front teeth, they’re good for checking shape and length. They’re not good for checking shade, because our printed provisionals come in one shade, with none of the depth of the final ceramic. So nobody judged color on them. The patient wore them for 10 days and was happy with the outline .

Step 3: Four Pressed Emax Crowns From One Lot

The four pressed emax crowns came from one ingot lot, pressed together, so the four units start from the same material . Ingot choice followed the A3 stump and the A2 target. Ivoclar makes IPS e.max Press ingots in several translucency levels, and the stump decides how much translucency the crown can take.

Step 4: Stain, glaze and texture

Pressed emax crowns for front esthetic work go to technicians with 10 or more years at the bench. On these emax crowns front teeth :

Body: A2, a touch warmer at the necks so the crowns sit well next to the natural canines.
Edges: a light gray-blue incisal band, taken from the pre-op photos.
Texture: the light horizontal lines the old teeth had, read off the PLY scan and photos.
Glaze: thin, polished back so it doesn't look wet.

Each stain, dilution and firing went on the case file . We also keep the contour and anatomy on record, so a later crown for this patient can match these four.

Step 5: Final checks

A QC technician who didn’t make the anterior emax crowns checked them before shipping:

Fit: margins, inner surfaces and seating on the model.
Contacts: each of the three contacts between crowns, plus #7 against #6 and #10 against #11 .
Bite: centric, protrusive and lateral, against the opposing scan. Palatal contacts on #8 and #9 checked against the pre-op bite .
Shape: the finished crowns scanned and laid over the approved design. Facial deviation stayed within 0.1 mm, except the embrasure the dentist asked us to change .
Esthetics: color, translucency, texture and symmetry, under a standard light.

Emax Crowns Front Teeth: The Finished Result

The dentist tried the pressed emax crowns in with try-in paste, then bonded them . Cement choice, bonding steps and isolation were theirs.

Design target
What happened at seating
Copy the pre-op outline
Facial outline matched the pre-op photos side by side, per the dentist
Enough ceramic on #8 and #9
1.2–1.3 mm on the facial, from the rescan
Wider #8/#9 embrasure
Opened 0.2 mm, as approved
Same bite as before
One light protrusive touch on #9, adjusted and polished chairside
A2 next to natural canines
Read as one set in the smile photos, per the dentist
All four seat on first delivery
No remakes

What the dentist told us

They said the patient’s first reaction was that the teeth looked “like mine, just cleaner.” That was the brief .

What we gave up

Tooth structure: another 0.4–0.5 mm off the facial of #8 and #9 .
Time: one extra visit, plus courier days for the guide and provisionals .
A perfect copy: the #8/#9 embrasure is 0.2 mm wider than before, on purpose .

Sending Us Your Own Emax Crowns Front Teeth Case

If your anterior emax crowns need to keep a shape the patient already likes, here’s what helps us most:

A pre-op scan or model, taken before any prep. PLY for scans. This is the file we copy from.
The prep scan, opposing arch and bite. Trace the margins yourself if your scanner allows it.
Photos with a 5500K ring or twin flash. Shade tab next to the target tooth, and next to the stump, in the same frame.
Your Rx: use our Rx form. Write "copy pre-op shape" and list any changes you want, like an embrasure or a length. Thin zones show up in the design preview, before pressing.

The terms:

Lab time: generally 5–7 working days for e.max crowns, design approval included. Time spent waiting on replies, rescans or missing files isn't counted.
Shipping: you pay to send impressions or models to us. We pay to ship finished work back, remakes included.
Warranty: 3 years on crowns. Open margins or contacts, a high bite, a crown that won't seat, a wrong shade or poor shape all get remade free.
Quotes: itemized to your Rx, not one bundled price. Ask for the price list.

How to package and ship is on our how to send a case page. More on materials and options is on our e.max crowns and bridges page and our e.max lab page.

Everything is made in our own four labs in Shenzhen and Huizhou, China. We’ve been doing this since 2012, with about 460 people, and nothing gets outsourced. Istar is an FDA-registered establishment, Registration Number 3039441248, which you can check in FDA’s establishment database. The lab works under ISO 13485. You can also book a factory visit or a video tour.

Got front teeth where the shape has to stay? Send your next emax crowns front teeth case as a test case, and we’ll show you the thickness map before we press anything. Send your first case or talk to us.

FAQ

Can you copy my provisionals instead of the pre-op teeth?

Yes. If the patient has worn provisionals they like, scan them in the mouth and send that scan with the prep scan. We copy the outer shape from it the same way, onto pressed emax crowns.

We’ll design to the Rx and the photos, but it won’t be an exact copy, since a photo has no depth. Tell us that up front, so we both know what “same shape” can mean on that case.

Yes. A physical tab or the old crown can travel with the case, and the technician will work next to it.

A shade change from your side isn’t a free remake. That’s why we send the design first, and why it pays to settle shade before pressing.

Yes. Ask, and we’ll give you the brand, origin, lot number and certificate for that case. We won’t swap a material without your OK, written or verbal.

Rush is free for clients sending 10 or more cases a month. We guarantee the ship date. Arrival depends on customs, so we can’t guarantee that part.